Publication Date |
1997 |
Personal Author |
Jetter, J. J.; Smith, N. D.; Ratanaphruks, K.; Ng, M. S.; Tufts, M. W.; Delafield, F. R. |
Page Count |
12 |
Abstract |
The paper gives results of an evaluation of a proprietary refrigerant, Ikon-12, as an alternative to hydrofluorocarbon (HFC)-134a for automotive air conditioning. In preliminary tests, Ikon-12 was found to be compatible with a polyolester lubricant and engineering materials. Refrigeration capacity and efficiency for Ikon-12 compared favorably to those for HFC-134a. In a preliminary durability test, Ikon-12 refrigerant showed no significant chemical breakdown after extended operation with an elevated compresssor discharge temperature. |
Keywords |
|
Source Agency |
|
Corporate Authors |
Acurex Environmental Corp., Research Triangle Park, NC.; Environmental Protection Agency, Research Triangle Park, NC. Air |
Supplemental Notes |
Presented at the SAE International Congress and Exposition, Detroit, MI., February 24-27, 1997. Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Prevention and Control Div. |
Document Type |
Conference Proceedings |
Title Note |
Rept. for Oct 95-Jun 96. |
NTIS Issue Number |
199721 |
Contract Number |
|