The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:

Control of Wind-Induced Tall Building Vibration by Tuned Mass Dampers.


PB90259334

Publication Date 1990
Personal Author Xu, Y. L.; Kwok, K. C. S.; Samali, B.
Page Count 49
Abstract Wind tunnel model tests and theoretical analyses were conducted to investigate the effectiveness of tuned mass dampers in suppressing wind-induced tall building motion. The tall building model was a 1:400 scale aeroelastic model of the CAARC Standard Tall Building. The model and the tuned mass damper models of different parameters were designed and tested in a wind tunnel with properly simulated atmospheric boundary layer flow. The aeroelastic test of the CAARC model demonstrated the effectiveness of the tuned mass damper system in suppressing the dynamic response of the building. The parametric study of passive tuned mass dampers, leading to theoretical analysis and design of an effective and efficient tuned mass damper system, was based on excitation spectra which were directly measured from the wind tunnel model tests. Theoretical results were in good agreement with the test results. The analytical results further indicated that the effectiveness of tuned mass dampers can be enhanced by the inclusion of an active control system.
Keywords
  • Buildings
  • Wind tunnel models
  • Damping
  • Dynamic response
  • Wind pressure
  • Vibration
  • Loads(Forces)
  • Mathematical models
  • Foreign technology
  • Wind loads
  • Wind tunnel tests
Source Agency
  • Invalid Source Agency Code
NTIS Subject Category
  • 51A - Aerodynamics
  • 89D - Structural Analyses
  • 46E - Structural Mechanics
Corporate Authors Sydney Univ. (Australia). School of Civil and Mining Engineering.
Document Type Technical Report
Title Note Research rept.
NTIS Issue Number 199022
Control of Wind-Induced Tall Building Vibration by Tuned Mass Dampers.
Control of Wind-Induced Tall Building Vibration by Tuned Mass Dampers.
PB90259334

  • Buildings
  • Wind tunnel models
  • Damping
  • Dynamic response
  • Wind pressure
  • Vibration
  • Loads(Forces)
  • Mathematical models
  • Foreign technology
  • Wind loads
  • Wind tunnel tests
  • Invalid Source Agency Code
  • 51A - Aerodynamics
  • 89D - Structural Analyses
  • 46E - Structural Mechanics
Loading