Publication Date |
1981 |
Personal Author |
Salvendy, G. |
Page Count |
163 |
Abstract |
Appendices to a report on the self tripping light curtain safety device for machine presses were presented, including a fault tree analysis, failure mode analysis, reliability formulae and probabilities, operation sequence of control relays, tables of raw production data, productivity data plots, a computer program for monitoring and recording physiological data, worker questionnaires, and physiological data plots. The analytical procedure and fault tree results of fault tree analysis were described, based on system components. Safety was differentiated into self tripping safety (probability that the press will not operate while the curtain is obstructed) and guard safety (probability that the press will stop operating when the curtain is broken). Failure mode analysis included description of basic failure modes of light curtain unit electronic components, failure modes for relays, and failure rate data for each functional block. |
Keywords |
|
Source Agency |
|
NTIS Subject Category |
|
Corporate Authors |
Purdue Univ., Lafayette, IN. School of Industrial Engineering.; National Inst. for Occupational Safety and Health, Rockville, MD. |
Supplemental Notes |
See also Phase 1 Volume 1, PB87-189197. Sponsored by National Inst. for Occupational Safety and Health, Rockville, MD. |
Document Type |
Technical Report |
NTIS Issue Number |
198718 |
Contract Number |
|