National Technical Reports Library - NTRL

National Technical Reports Library

The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:

Reverse Performance Characteristics of Main Mine Fans.


PB84143726

Publication Date 1983
Personal Author Dunn, M. F.; Bhattacharya, S.; Rajaram, V.
Page Count 66
Abstract During a mine fire or other emergency, it may be desirable to reverse the airflow in order to provide an escapeway or to isolate a fire. Also, in colder areas, the airflow may be reversed to prevent ice buildup. When reversing main mine fans, the mine operator usually does not know what operating characteristics of flow and pressure to expect. Laboratory and field tests of vane-axial main mine fans in the 7- to 9-ft-diam size range were conducted to establish forward and reverse performance characteristics under controlled conditions and at typical mine installations. The data obtained suggest that reverse performance characteristics are dependent upon the blade angle and the hub-to-tip ratio. There is also evidence that reverse performance can be predicted for a family of blade angles and a given hub-to-tip ratio. Generally, quantity of air is 30% to 65% less in reverse than when operating in the normal forward mode.
Keywords
  • Mine ventilation
  • Ventilation fans
  • Vaneaxial fans
  • Air flow
  • Mine fires
  • Field tests
  • Mine safety
  • Reverse flow
Source Agency
  • Bureau of Mines
NTIS Subject Category
  • 48A - Mineral Industries
Corporate Authors Engineers International, Inc., Westmont, IL.; Bureau of Mines, Washington, DC.
Document Type Technical Report
Title Note Open file rept. 23 Jan 81-15 Jun 83.
NTIS Issue Number 198408
Contract Number
  • J0308044
Reverse Performance Characteristics of Main Mine Fans.
Reverse Performance Characteristics of Main Mine Fans.
PB84143726

  • Mine ventilation
  • Ventilation fans
  • Vaneaxial fans
  • Air flow
  • Mine fires
  • Field tests
  • Mine safety
  • Reverse flow
  • Bureau of Mines
  • 48A - Mineral Industries
  • J0308044