The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

Determination of the Pure-Tone to Noise-Band Transfer Function for Audiometric Testing and Fit Testing of Hearing Protectors.


PB2015102723

Publication Date 2012
Personal Author Flamme, G. A.
Page Count 26
Abstract This report details the results of the Pure Tone to Noise Band Transfer Function project. The purpose of this project was to examine the transfer function for thresholds obtained under HDA200 circumaural earphones using pure tone, equivalent rectangular noise bands, and 1/3 octave noise bands to thresholds obtained using TDH-39P supra-aural earphones. The objective is to obtain both correction factors for thresholds and also identify any differences in the reliability of threshold estimates obtained via any of the four methods. The results of this project suggest that (1) for the stimuli and calibration used in this project, only small adjustments are possibly needed to reach equivalent TDH-39P thresholds, (2) pure tone thresholds obtained with HDA200 circumaural earphones have reliability equal to or better than those obtained using TDH-39P earphones, (3) the reliability of noise band thresholds improves with broader stimulus bandwidth and is either equal to or better than pure tone thresholds, and (4) frequency-specificity begins to decline with stimulus bandwidths over greater than one ERB, which could complicate early detection of focal hearing changes. We believe that there are two recommendations supported by this project. First, these data support a recommendation for the use of HDA200 earphones for audiometric monitoring. Second, these data support the use of noise bands, preferably ERB noises, as stimuli for audiometric monitoring.
Keywords
  • Hearing
  • Hearing tests
  • Hearing threshold
  • Audiological testing
  • Analytical processes
  • Noise bands
Source Agency
  • National Institute for Occupational Safety and Health
NTIS Subject Category
  • 57A - Anatomy
  • 95G - Protective Equipment
Corporate Authors Western Michigan Univ., Kalamazoo.; National Inst. for Occupational Safety and Health, Washington, DC.
Supplemental Notes Sponsored by National Inst. for Occupational Safety and Health, Washington, DC.
Document Type Technical Report
NTIS Issue Number 201509
Contract Number
  • CDC/NIOSH-254-2011-M-40487
Determination of the Pure-Tone to Noise-Band Transfer Function for Audiometric Testing and Fit Testing of Hearing Protectors.
Determination of the Pure-Tone to Noise-Band Transfer Function for Audiometric Testing and Fit Testing of Hearing Protectors.
PB2015102723

  • Hearing
  • Hearing tests
  • Hearing threshold
  • Audiological testing
  • Analytical processes
  • Noise bands
  • National Institute for Occupational Safety and Health
  • 57A - Anatomy
  • 95G - Protective Equipment
  • CDC/NIOSH-254-2011-M-40487