National Technical Reports Library - NTRL

National Technical Reports Library

The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

New Air Sampling System for Long Term Sampling.


PB2011109750

Publication Date 2008
Personal Author Rossner, A.; Wick, D. P.
Page Count 26
Abstract A continuing challenge in occupational hygiene is that of accurately estimating a worker's exposure to the multitude of airborne chemicals found in the workplace and surrounding community. Hence, the development of new methods that will permit more effective sampling of contaminants in the workplace is essential to ensure that accurate exposure assessments are completed. Over the last five years a capillary flow controller was designed and tested in laboratory and field studies. The very low flow rate provided by the capillary flow controller permits a sample to be collected over an extended period of time when used with a small portable evacuated canister. The initial research focused on the development of the capillary-canister and the evaluation of its ability to collect representative air samples. However, capillary flow controllers exhibit a characteristic drop in flow rate with time. The time dependent flow rate coupled with concentration changes in the sampling environment could result in a sampling bias. The focus of this study was performance evaluation based on field studies and prediction of the sampling bias. As part of this study, the capillary canister system was redesigned to make it less expensive, more compact, and more acceptable to the person wearing the sampler. The performance of the capillary canisters was evaluated by conducting field experiments at two different locations. Twenty-four paired samples were collected using canisters and diffusive badges. The paired t-test performed on the personal samples showed no statistical difference between the two methods. The model developed to predict the sampling bias associated with capillary canisters was experimentally validated. A series of predicted worst-case scenarios involving peak concentrations were experimentally simulated at three sampling time durations: 8 hrs, 24 hrs and 40 hrs. Three canisters, a gas chromatography (GC), and photo ionization detector were used to monitor the concentration profile during the experiments. The bias between the canisters and the GC was calculated from the experimental values. When analytical errors were considered, the experimental values approached the predicted model values.
Keywords
  • Air sampling
  • Airborne particles
  • Air pollution monitoring
  • Air quality measurement
  • Quantitative analysis
  • Sampling methods
  • Environmental exposure
  • Workplace studies
  • Chemical hypersensitivity
  • Measurement equipment
  • Long term sampling
Source Agency
  • National Institute for Occupational Safety and Health
Corporate Authors Clarkson Univ., Potsdam, NY.; National Inst. for Occupational Safety and Health, Washington, DC.
Supplemental Notes Sponsored by National Inst. for Occupational Safety and Health, Washington, DC.
Document Type Technical Report
NTIS Issue Number 201119
New Air Sampling System for Long Term Sampling.
New Air Sampling System for Long Term Sampling.
PB2011109750

  • Air sampling
  • Airborne particles
  • Air pollution monitoring
  • Air quality measurement
  • Quantitative analysis
  • Sampling methods
  • Environmental exposure
  • Workplace studies
  • Chemical hypersensitivity
  • Measurement equipment
  • Long term sampling
  • National Institute for Occupational Safety and Health
Loading