National Technical Reports Library - NTRL

National Technical Reports Library

The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload PDF
Download

Ventilation and Indoor Air Quality in New Homes.


PB2011105857

Publication Date 2009
Personal Author Offermann, F. J.
Page Count 426
Abstract Concerns have been raised regarding whether homeowners use windows, exhaust fans, and other mechanical ventilation devices enough to remove indoor air contaminants and excess moisture. In a multi-season study of ventilation and indoor air quality of 108 new single-family, detached homes in California, window use, ventilation rates, and air contaminant concentrations were measured. The median 24-hour outdoor air exchange rate was 0.26 air changes per hour; 67 percent of the homes were below the California building code requirement of 0.35 air changes per hour; and 32 percent of the homes did not use their windows. Home-to-garage pressure testing guidelines were exceeded in 65 percent of the homes. The median indoor formaldehyde concentration was 36 micrograms per cubic meter (range of 4.8 to 136 micrograms per cubic meter). Nearly all homes had formaldehyde concentrations that exceeded guidelines for cancer and chronic irritation, while 59 percent exceeded guidelines for acute irritation. In conclusion, new single-family detached homes in California are built relatively airtight, can have very low outdoor air exchange rates, and can often exceed exposure guidelines for air contaminants with indoor sources, such as formaldehyde and some other volatile organic compounds. Mechanical ventilation systems are needed to provide a dependable, continuous supply of outdoor air to new homes, and reductions of various indoor formaldehyde sources are also needed.
Keywords
  • Indoor air quality
  • Ventilation
  • Houses
  • Contaminants
  • Moisture
  • Carbon monoxide
  • Emission
  • Formaldehyde
  • Particulates
  • Building codes
  • California
  • Exhaust fans
  • Windows
Source Agency
  • California Air Resources Board Resources Agency
Corporate Authors Indoor Environmental Engineering, San Francisco, CA.; California Energy Commission, Sacramento.; California State Air Resources Board, Sacramento. Research Div.
Supplemental Notes Prepared in cooperation with California Energy Commission, Sacramento. Sponsored by California State Air Resources Board, Sacramento. Research Div.
Document Type Technical Report
Title Note Final rept.
NTIS Issue Number 201115
Ventilation and Indoor Air Quality in New Homes.
Ventilation and Indoor Air Quality in New Homes.
PB2011105857

  • Indoor air quality
  • Ventilation
  • Houses
  • Contaminants
  • Moisture
  • Carbon monoxide
  • Emission
  • Formaldehyde
  • Particulates
  • Building codes
  • California
  • Exhaust fans
  • Windows
  • California Air Resources Board Resources Agency
Loading