National Technical Reports Library - NTRL

National Technical Reports Library

The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

High Energy X-Ray and Neutron Modeling and Digital Imaging for Nondestructive Testing Applications.


PB2001105764

Publication Date 2001
Personal Author Davis, A. W.; Hills, C. R.; Sheats, M. J.; Claytor, T. N.
Page Count 14
Abstract Adapting amorphous silicon imagers to the rigors of nondestructive evaluation has required the creation of new tools and techniques for successful detection of flaws in dense objects. At Los Alamos Nationrd Laboratory, extensive use of digital imagers and a desire to replace fihn with digital systems has led to additional research into modeling and simulation with an ultimate goal of improved techniques for using these imagers. The imagers have been used with varying success at x-ray energies ranging from 70 keV to 20 MeV, as well as with a variety of neutron energies at the Los Ahunos Neutron Science Center (L4NSCE). To simulate these diverse situations, a new version of the Monte Carlo Neutron/Photon (MCNP) simulation package, developed at Los Alamos, is employed (MCNP-X). The rapid simulation of various setups allows the rapid development of techniques without extensive and costly experimentation or test block The simulations cover digital radiography as well as computed tomography. The results of these simulations leads to several techniques for digital radiography and computed tomography unique to amorphous silicon imagers, and provides additional information concerning the transition from film to digital imaging. Specifically, techniques have been developed to use the order of magnitude speed advantage of amorphous silicon detectors to provide density resolution in ways not possible with fihn. Also, the viability of amorphous silicon detectors at extremely high energies (1-20 MeV) is simulated and tested experimentally.
Keywords
  • Neutron radiography
  • Nondestructive testing
  • Radiography
  • Tomography
  • X-ray radiography
Source Agency
  • Technical Information Center Oak Ridge Tennessee
NTIS Subject Category
  • 41G - Quality Control & Reliability
  • 77G - Radioactive Wastes & Radioactivity
  • 94J - Nondestructive Testing
Corporate Authors Los Alamos National Lab., NM.; Department of Energy, Washington, DC.
Supplemental Notes Submitted to SPIE Annual Meeting, August 2, 2000. Sponsored by Department of Energy, Washington, DC.
Document Type Technical Report
NTIS Issue Number 200117
Contract Number
  • DE-W-7405-ENG-36
High Energy X-Ray and Neutron Modeling and Digital Imaging for Nondestructive Testing Applications.
High Energy X-Ray and Neutron Modeling and Digital Imaging for Nondestructive Testing Applications.
PB2001105764

  • Neutron radiography
  • Nondestructive testing
  • Radiography
  • Tomography
  • X-ray radiography
  • Technical Information Center Oak Ridge Tennessee
  • 41G - Quality Control & Reliability
  • 77G - Radioactive Wastes & Radioactivity
  • 94J - Nondestructive Testing
  • DE-W-7405-ENG-36