National Technical Reports Library - NTRL

National Technical Reports Library

The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

Characterization of Gatewell Orifice Lighting at the Bonneville Dam Second Powerhouse and Compendium of Research on Light Guidance with Juvenile Salmonids. Final Report.


DE2008940756

Publication Date 2008
Personal Author Mueller, R. P.; Simmons, M. A.; Bonebrake, C. A.
Page Count 55
Abstract The goal of the study described in this report is to provide U.S. Army Corps of Engineers (USACE) biologists and engineers with general design guidelines for using artificial lighting to enhance the passage of juvenile salmonids into the collection channel at the Bonneville Dam second powerhouse (B2). During fall 2007, Pacific Northwest National Laboratory (PNNL) researchers measured light levels in the field at one powerhouse orifice through which fish must pass to reach the collection channel. Two light types were evaluated light-emitting diode (LED)-lights and halogen spot lights. Additional measurements with mercury lamps were made at the PNNL Aquatic Research Laboratory to determine baseline intensity of the current lighting. A separate chapter synthesizes the relevant literature related to light and fish guidance for both field and laboratory studies. PNNL will also review the Corps plans for existing lighting protocol at all of the Portland District projects and help develop a uniform lighting scheme which could be implemented. The specific objectives for this study are to 1. Create a synthesis report of existing lighting data for juvenile salmonid attraction and deterrence and how the data are used at fish bypass facilities. 2. Evaluate current B2 orifice lighting conditions with both LED and halogen sources. 3. Make recommendations as to what lighting intensity, source, and configuration would improve passage at the B2 orifices. 4. Review USACE plans for retrofit of existing systems (to be assessed at a later date).
Keywords
  • Salmon
  • Lighting systems
  • Design
  • Salmonics
  • Juveniles
  • Orifices
  • Performance tests
  • Literature reviews
  • Hydroelectric energy
  • Field tests
  • Laboratory tests
  • Lights
  • Light intensities
  • Fish passage facilities
  • Artificial lighting
  • Bonneville Dam Second Powerhouse
  • Gatewell Orifice Structures
  • Orifica lighting
Source Agency
  • Technical Information Center Oak Ridge Tennessee
Corporate Authors Pacific Northwest National Lab., Richland, WA.; Department of Energy, Washington, DC.; Army Engineer Div. North Pacific, Portland, OR.
Supplemental Notes Prepared in cooperation with Army Engineer Div. North Pacific, Portland, OR. Sponsored by Department of Energy, Washington, DC.
Document Type Technical Report
NTIS Issue Number 200908
Contract Number
  • DE-AC05-76RL01830
Characterization of Gatewell Orifice Lighting at the Bonneville Dam Second Powerhouse and Compendium of Research on Light Guidance with Juvenile Salmonids. Final Report.
Characterization of Gatewell Orifice Lighting at the Bonneville Dam Second Powerhouse and Compendium of Research on Light Guidance with Juvenile Salmonids. Final Report.
DE2008940756

  • Salmon
  • Lighting systems
  • Design
  • Salmonics
  • Juveniles
  • Orifices
  • Performance tests
  • Literature reviews
  • Hydroelectric energy
  • Field tests
  • Laboratory tests
  • Lights
  • Light intensities
  • Fish passage facilities
  • Artificial lighting
  • Bonneville Dam Second Powerhouse
  • Gatewell Orifice Structures
  • Orifica lighting
  • Technical Information Center Oak Ridge Tennessee
  • DE-AC05-76RL01830
Loading