The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

Seven Channel Multi-Collector Isotope Ratio Mass Spectrometer.


DE2008936629

Publication Date 2008
Personal Author Appelhans, A. D.
Page Count 9
Abstract A new magnetic sector mass spectrometer that utilizes seven full-sized discrete dynode electron multipliers operating simultaneously has been designed, constructed and is in preliminary testing. The instrument utilizes a newly developed ion dispersion lens that enables the mass dispersed individual isotope beams to be separated sufficiently (35 mm) to allow a full-sized discrete dynode pulse counting multiplier to be used for each beam. The ion dispersion lens is a two element electrostatic 90 degree sector device that causes the beam-to-beam dispersion to increase faster than the intra-beam dispersion. Each multiplier is contained in an isolated case with a deflector/condenser lens at the entrance. A 9-sample filament cartridge is mounted on a micro-manipulator two-axis stage that enables adjustment of the filament position with 10 micron resolution within the ion lens. Results of initial testing with actinides will be presented.
Keywords
  • Spectrometer
  • Isotope ratio
  • Mass spectrometry
  • Dynode electron multipliers
  • Ion dispersion lens
  • Testing
Source Agency
  • Technical Information Center Oak Ridge Tennessee
Corporate Authors Idaho National Laboratory, Idaho Falls, ID.; Department of Energy, Washington, DC.
Supplemental Notes Sponsored by Department of Energy, Washington, DC.
Document Type Technical Report
NTIS Issue Number 200908
Contract Number
  • DE-AC07-99ID-13727
Seven Channel Multi-Collector Isotope Ratio Mass Spectrometer.
Seven Channel Multi-Collector Isotope Ratio Mass Spectrometer.
DE2008936629

  • Spectrometer
  • Isotope ratio
  • Mass spectrometry
  • Dynode electron multipliers
  • Ion dispersion lens
  • Testing
  • Technical Information Center Oak Ridge Tennessee
  • DE-AC07-99ID-13727
Loading