The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload PDF
Download

Cygnus Trigger System.


DE2008926633

Publication Date 2008
Personal Author Corrow, G.; Hansen, M.; Henderson, D.; Mitton, C.
Page Count 6
Abstract The Cygnus Dual Beam Radiographic Facility consists of two radiographic sources (Cygnus 1, Cygnus 2) each with a dose rating of 4 rads at 1 m, and a 1-mm diameter spot size. The electrical specifications are: 2.25 MV, 60 kA, 60 ns. This facility is located in an underground environment at the Nevada Test Site (NTS). These sources were developed as a primary diagnostic for subcritical tests, which are single-shot, high-value events. In such an application there is an emphasis on reliability and reproducibility. A robust, low-jitter trigger system is a key element for meeting these goals. The trigger system was developed with both commercial and project-specific equipment. In addition to the traditional functions of a trigger system there are novel features added to protect the investment of a high-value shot. Details of the trigger system, including elements designed specifically for a subcritical test application, will be presented. The individual electronic components have their nominal throughput, and when assembled have a system throughput with a measured range of jitter. The shot-to-shot jitter will be assessed both individually and in combination. Trigger reliability and reproducibility results will be presented for a substantial number of shots executed at the NTS.
Keywords
  • Jitter
  • Subcriticality
  • Radiography
  • Nevada Test Site
  • Reliability
  • Reproducibility
  • Trigger system
  • Low jitter
Source Agency
  • Technical Information Center Oak Ridge Tennessee
Corporate Authors National Security Technologies, LLC., Las Vegas, NV.; Department of Energy, Washington, DC.
Supplemental Notes Sponsored by Department of Energy, Washington, DC.
Document Type Technical Report
NTIS Issue Number 200824
Contract Number
  • DE-AC52-06NA25946
Cygnus Trigger System.
Cygnus Trigger System.
DE2008926633

  • Jitter
  • Subcriticality
  • Radiography
  • Nevada Test Site
  • Reliability
  • Reproducibility
  • Trigger system
  • Low jitter
  • Technical Information Center Oak Ridge Tennessee
  • DE-AC52-06NA25946
Loading