The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

Characterization of the Transient Response of the ILS with One Module Installed to Heatup Changes in Power Level and Cooldown.


DE2008924505

Publication Date 2007
Personal Author Condie, K. G.; Stoots, C. M.; O'Brien, J. E.; Herring, J. S.
Page Count 37
Abstract This report provides documentation of the initial startup and testing of the first electrolysis module in the Idaho National Laboratory (INL) High Temperature Steam Electrolysis Integrated Laboratory Scale (ILS) facility. Initial shakedown testing of the INL ILS experimental facility commenced on August 22, 2007. This fulfilled a DOE Level 2 milestone. Heatup of the first ILS module started at approximately 4:10 PM on September 24, 2007. Initial module testing continued for 420 hours. The test average H2 production rate was approximately 1.3 Nm3/hr (0.116 kg H2/hr), with a peak measured value of over 2 Nm3/hr (0.179 kg H2/hr). Significant module performance degradation was observed over the first 250 hours, after which no further degradation was noted for the remainder of the test. Once all test objectives had been successfully met, the test was terminated in a controlled fashion. Discussion is included concerning several modifications that will be incorporated into the facility components to improve reliability and ease of operation for future long term testing.
Keywords
  • Hydrogen
  • Electrolysis
  • Documentation
  • Modifications
  • Production
  • Reliability
  • High temperature
  • Steam
  • Testing
  • Transients
  • Integrated Laboratory Scale(ILS)
  • Idaho National Laboratroy
Source Agency
  • Technical Information Center Oak Ridge Tennessee
Corporate Authors Idaho National Laboratory, Idaho Falls, ID.; Department of Energy, Washington, DC.
Supplemental Notes Sponsored by Department of Energy, Washington, DC.
Document Type Technical Report
NTIS Issue Number 200822
Characterization of the Transient Response of the ILS with One Module Installed to Heatup Changes in Power Level and Cooldown.
Characterization of the Transient Response of the ILS with One Module Installed to Heatup Changes in Power Level and Cooldown.
DE2008924505

  • Hydrogen
  • Electrolysis
  • Documentation
  • Modifications
  • Production
  • Reliability
  • High temperature
  • Steam
  • Testing
  • Transients
  • Integrated Laboratory Scale(ILS)
  • Idaho National Laboratroy
  • Technical Information Center Oak Ridge Tennessee
Loading