The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

Quantifying Deep Vadose Zone Soil Water Potential Changes at a Waste Disposal Site.


DE2008920408

Publication Date 2007
Personal Author Hubbell, J. M.; McElroy, D. L.
Page Count 8
Abstract Recent advances in moisture monitoring using tensiometers has resulted in long-duration, high quality data sets from within the deep vadose zone. A network of about 30 advanced tensiometers in 18 wells provided field-scale data to monitor soil water potential conditions and movement in the subsurface in and around a mixed waste disposal site at depths ranging from 6 to over 67 m below land surface (bls). Sensors are located in both sediments and fractured rock within the geologic profile and some have been in operation for over 10 years. The moisture monitoring was able to detect long term declines in soil water potential in response to lower than normal precipitation and resultant infiltration over the time period from 2000 to 2004. This trend was reversed in 2005 and 2006 in more than half of the monitoring sites over the 6 to 33 m depth interval and in several monitoring sites from 33 to 67 m, in response to above normal precipitation. These tensiometer data have the potential to effectively and rapidly validate that a remedial action such as placement of an ET cover would be successful in reducing the water moisture movement inside the disposal area to levels similar to those in undisturbed sites outside of the disposal area. This paper will describe the instrument design, how the instruments were installed, and the resultant data from this monitoring system.
Keywords
  • Tensiometers
  • Waste disposal sites
  • Soil moisture
  • Soil water potential
  • Moisture monitoring
  • Data acquisition systems
  • Ground disposal
  • Hydrology
  • Instruments
  • Infiltration
  • Monitoring wells
  • Vadose zone monitoring
  • Deep vadose zones
Source Agency
  • Technical Information Center Oak Ridge Tennessee
Corporate Authors Idaho National Engineering Lab., Idaho Falls.; Department of Energy, Washington, DC.
Supplemental Notes Sponsored by Department of Energy, Washington, DC.
Document Type Technical Report
NTIS Issue Number 200817
Contract Number
  • DE-AC07-99ID-13727
Quantifying Deep Vadose Zone Soil Water Potential Changes at a Waste Disposal Site.
Quantifying Deep Vadose Zone Soil Water Potential Changes at a Waste Disposal Site.
DE2008920408

  • Tensiometers
  • Waste disposal sites
  • Soil moisture
  • Soil water potential
  • Moisture monitoring
  • Data acquisition systems
  • Ground disposal
  • Hydrology
  • Instruments
  • Infiltration
  • Monitoring wells
  • Vadose zone monitoring
  • Deep vadose zones