The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

Manufactured Home Testing in Simulated and Naturally Occurring High Winds. WCTE 2006.


DE2007911197

Publication Date 2006
Personal Author Richins, W. D.; Larson, T. K.; Lacy, J. M.; Kobbe, R. G.
Page Count 9
Abstract A typical double-wide manufactured home was tested in simulated and naturally occurring high winds to understand structural behavior and improve performance during severe windstorms. Seven lateral load tests were conducted on a double-wide manufactured home at a remote field test site in Wyoming. An extensive instrumentation package monitored the overall behavior of the home and collected data vital to validating computational software for the manufactured housing industry. The tests were designed to approach the design load of the home without causing structural damage, thus allowing the behavior of the home to be accessed when the home was later exposed to high winds (to 80-mph). The data generally show near-linear initial system response with significant non-linear behavior as the applied loads increase. Load transfer across the marriage line is primarily compression. Racking, while present, is very small. Interface slip and shear displacement along the marriage line are nearly insignificant. Horizontal global displacements reached 0.6 inch. These tests were designed primarily to collect data necessary to calibrate a desktop analysis and design software tool, MHTool, under development at the Idaho National Laboratory specifically for manufactured housing. Currently available analysis tools are, for the most part, based on methods developed for 'stick built' structures and are inappropriate for manufactured homes.
Keywords
  • Prefabricated buildings
  • Mobile homes
  • Wind loads
  • Structural analysis
  • Building codes
  • Design
  • Hurricanes
  • Damage assessment
  • Performance evaluation
  • Testing
  • Computer programs
Source Agency
  • Technical Information Center Oak Ridge Tennessee
Corporate Authors Argonne National Lab., Idaho Falls, ID.; Department of Energy, Washington, DC.
Supplemental Notes Sponsored by Department of Energy, Washington, DC.
Document Type Technical Report
NTIS Issue Number 200801
Manufactured Home Testing in Simulated and Naturally Occurring High Winds. WCTE 2006.
Manufactured Home Testing in Simulated and Naturally Occurring High Winds. WCTE 2006.
DE2007911197

  • Prefabricated buildings
  • Mobile homes
  • Wind loads
  • Structural analysis
  • Building codes
  • Design
  • Hurricanes
  • Damage assessment
  • Performance evaluation
  • Testing
  • Computer programs
  • Technical Information Center Oak Ridge Tennessee
Loading