National Technical Reports Library - NTRL

National Technical Reports Library

The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload PDF
Download

Post-Closure Inspection and Monitoring Report for Corrective Action Unit 417: Central Nevada Test Area - Surface, Hot Creek Valley, Nevada, For Calendar Year 2004.


DE2006850249

Publication Date 2005
Page Count 138
Abstract This post-closure inspection and monitoring report has been prepared according to the stipulations laid out in the Closure Report (CR) for Corrective Action Unit (CAU) 417, Central Nevada Test Area (CNTA) - Surface (U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Office (NNSA/NV), 200 1 ), and the Federal Facility Agreement and Consent Order (FFACO, 1996). This report provides an analysis and summary of site inspections, subsidence surveys, meteorological information, and soil moisture monitoring data for CAU 417, which is located in Hot Creek Valley, Nye County, Nevada. This report covers Calendar Year 2004. Inspections at CAU 417 are conducted quarterly to document the physical condition of the UC- 1, UC-3, and UC-4 soil covers, monuments, signs, fencing, and use restricted areas. The physical condition of fencing, monuments, and signs is noted, and any unusual conditions that could impact the integrity of the covers are reported. The objective of the soil moisture monitoring program is to monitor the stability of soil moisture conditions within the upper 1.2 meters (m) (4 feet (ft)) of the UC- 1 Central Mud Pit (CMP) cover and detect changes that may be indicative of moisture movement exceeding the cover design performance expectations.
Keywords
  • Nevada Test Site
  • Closure
  • Streams
  • Monitoring
  • Stability
  • Inspections
  • Performance
  • Soil moisture
Source Agency
  • Technical Information Center Oak Ridge Tennessee
Corporate Authors National Nuclear Security Administration, Las Vegas, NV. Nevada Operations Office.; Department of Energy, Washington, DC.
Supplemental Notes Sponsored by Department of Energy, Washington, DC.
Document Type Technical Report
NTIS Issue Number 200617
Post-Closure Inspection and Monitoring Report for Corrective Action Unit 417: Central Nevada Test Area - Surface, Hot Creek Valley, Nevada, For Calendar Year 2004.
Post-Closure Inspection and Monitoring Report for Corrective Action Unit 417: Central Nevada Test Area - Surface, Hot Creek Valley, Nevada, For Calendar Year 2004.
DE2006850249

  • Nevada Test Site
  • Closure
  • Streams
  • Monitoring
  • Stability
  • Inspections
  • Performance
  • Soil moisture
  • Technical Information Center Oak Ridge Tennessee
Loading