National Technical Reports Library - NTRL

National Technical Reports Library

The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

Preparation of Metal Filter Element for Fail Safety in IGCC Filter Unit.


DE2005835840

Publication Date 2005
Page Count 12
Abstract Metal filter elements as the fail safety filter are fabricated by the methods using cold isostatic pressure (compress method) and binder (binder method) to form the filter element and tested in experimental and bench units. The fail safety filter on the filtration system is mounted additionally in order to intercept the particle leak when the main filter element is broken. So it should have two contrary functions of a high permeability and being plugged easily. The filter element having high porosity and high plugging property was fabricated by the bind method. It has the porosity more than 50%, showed very small pressure drop less than 10mmH2O at the face velocity of 0.15m/s, and plugged within 5 minutes with the inhibition of the particle leak larger than 4 (micro)m. The test result of corrosion tendency in IGCC gas stream at 500 C shows SUS310L material is very reasonable among SUS310, SUS316, Inconel 600, and Hastelloy X.
Keywords
  • Filters
  • Metal
  • Safety
  • Metal filter elements
  • Fabrication
  • Isostatic pressures
  • Binders (Materials)
  • Filtration
  • Particle leak
  • Leak detectors
  • Permeability
  • Plugging
  • Performance
  • Integrated Gasification Combined Cycle (IGCC)
Source Agency
  • Technical Information Center Oak Ridge Tennessee
Corporate Authors Gyoungsang National University, (Republic of Korea).; Department of Energy, Washington, DC.
Supplemental Notes Sponsored by Department of Energy, Washington, DC.
Document Type Technical Report
NTIS Issue Number 200521
Preparation of Metal Filter Element for Fail Safety in IGCC Filter Unit.
Preparation of Metal Filter Element for Fail Safety in IGCC Filter Unit.
DE2005835840

  • Filters
  • Metal
  • Safety
  • Metal filter elements
  • Fabrication
  • Isostatic pressures
  • Binders (Materials)
  • Filtration
  • Particle leak
  • Leak detectors
  • Permeability
  • Plugging
  • Performance
  • Integrated Gasification Combined Cycle (IGCC)
  • Technical Information Center Oak Ridge Tennessee
Loading