The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

Developments in the Measurement of Actinides and 1291 at LLNL by Accelerator Mass Spectrometry.


DE200515014496

Publication Date 2005
Personal Author Brown, T. A.; Marachetti, A. A.; Weyhenmeyver, C. E.; Knezovich, J. P.; Hamilton, T. F.; Nimz, G. J.
Page Count 14
Abstract The application of ultra-sensitive heavy isotope measurements continues to expand in a variety of fields relevant to the management of nuclear materials, including nuclear isotope forensics and radiobioassay. We have developed a heavy isotope accelerator mass spectrometry (AMS) system at Lawrence Livermore National Laboratory's (LLNL) Center for Accelerator Mass Spectrometry (CAMS). The system was designed particularly for the measurement of actinide concentrations and isotopic ratios, but also allows the measurement of other heavy isotopes such as (sup 129)I. The system includes a fast isotope switching capability that allows flexibility in isotope selection and for the quasi-continuous normalization to a reference isotope spike.
Keywords
  • Actinides
  • Iodine 129
  • Measurements
  • Mass spectrometry
  • Isotopes
  • Isotope ratio
  • Iodine 127
  • Accelerator mass spectrometry
Source Agency
  • Technical Information Center Oak Ridge Tennessee
Corporate Authors Lawrence Livermore National Lab., CA.; Department of Energy, Washington, DC.
Supplemental Notes Sponsored by Department of Energy, Washington, DC.
Document Type Technical Report
NTIS Issue Number 200604
Developments in the Measurement of Actinides and 1291 at LLNL by Accelerator Mass Spectrometry.
Developments in the Measurement of Actinides and 1291 at LLNL by Accelerator Mass Spectrometry.
DE200515014496

  • Actinides
  • Iodine 129
  • Measurements
  • Mass spectrometry
  • Isotopes
  • Isotope ratio
  • Iodine 127
  • Accelerator mass spectrometry
  • Technical Information Center Oak Ridge Tennessee
Loading