The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

Efficacy of Intermittent Ventilation for Providing Acceptable Indoor Air Quality.


DE2004834643

Publication Date 2004
Personal Author Sherman, M. H.
Page Count 28
Abstract Ventilation standards and guidelines typically treat ventilation as a constant and specify its value. In many circumstances a designer wishes to use intermittent ventilation, rather than constant ventilation, but there are no easy equivalencies available. This report develops a model of efficacy that allows one to calculate how much intermittent ventilation one needs to get the same indoor air quality as a the continuous value specified. We have found that there is a simple relationship between three dimensionless quantities: the temporal ventilation effectiveness (which we call the efficacy), the nominal turn-over and the under-ventilation fraction. This relationship allows the calculation of intermittent ventilation for a wide variety of parameters and conditions. We can use the relationship to define a critical time that separates the regime in which ventilation variations can be averaged over from the regime in which variable ventilation is of low effectiveness. We have found that ventilation load-shifting, temporary protection against poor outdoor air quality and dynamic ventilation strategies can be quite effective in low-density buildings such as single-family houses or office spaces.
Keywords
  • Ventilation systems
  • Indoor air quality
  • Standards
  • Guidelines
  • Models
  • Effectiveness
  • Residential buildings
  • Office buildings
  • Design
  • Air flow
  • Flow rate
  • Indoor air pollution
  • Flexibility
  • Recommendations
Source Agency
  • Technical Information Center Oak Ridge Tennessee
Corporate Authors Lawrence Berkeley National Lab., CA.; Department of Energy, Washington, DC. Assistant Secretary for Energy
Supplemental Notes Sponsored by Department of Energy, Washington, DC. Assistant Secretary for Energy Efficiency and Renewable Energy,.
Document Type Technical Report
NTIS Issue Number 200516
Efficacy of Intermittent Ventilation for Providing Acceptable Indoor Air Quality.
Efficacy of Intermittent Ventilation for Providing Acceptable Indoor Air Quality.
DE2004834643

  • Ventilation systems
  • Indoor air quality
  • Standards
  • Guidelines
  • Models
  • Effectiveness
  • Residential buildings
  • Office buildings
  • Design
  • Air flow
  • Flow rate
  • Indoor air pollution
  • Flexibility
  • Recommendations
  • Technical Information Center Oak Ridge Tennessee
Loading