National Technical Reports Library - NTRL

National Technical Reports Library

The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

Radiation Dose Measurements of the Insertion Devices Using Radiachromic Film Dosimeters.


DE2004834029

Publication Date 2004
Personal Author Alderman, J.; Semones, E.; Job, P. K.
Page Count 36
Abstract The Advanced Photon Source (APS) uses Nd-Fe-B permanent magnets in the insertion devices to produce x-rays for scientific research. Earlier investigations have exhibited varying degrees of demagnetization of these magnets due to irradiation from electron beams, (sup 60)Co (gamma)-rays, and high-energy neutrons. Radiation-induced demagnetization has been observed in the APS insertion devices and was first measured in December of 2001. Partial demagnetization has also been observed in insertion devices at the European Synchrotron Radiation Facility (ESRF), where Nd-Fe-B permanent magnets are also used. Growing concern for the lifetime of APS insertion devices, as well as the permanent magnets that will be used in next-generation, high-power light sources, like the FEL, resulted from the partial demagnetization observations made at both facilities. This concern in relation to radiation-induced demagnetization spurred a long-term project to measure and analyze the absorbed doses received by the APS insertion devices. The project required a reliable photon high-dose dosimetry technique capable of measuring absorbed doses greater than 10(sup 6) rad, which was not readily available at the APS. Through a collaboration with the National Institute of Standards and Technology (NIST), one such technique using radiachromic films was considered, tested, and calibrated at the APS. This consequently led to the implementation of radiachromic film dosimetry for measuring the absorbed doses received by the insertion devices for each of the APS runs.
Keywords
  • Advanced photon source
  • Radiation doses
  • Dosimeters
  • Dosimetry
  • Dosemeters
  • Photographic film dosemeters
  • Film dosimetry
  • Calibration
  • Radiachromic film dosimeters
  • Insertion devices
Source Agency
  • Technical Information Center Oak Ridge Tennessee
Corporate Authors Department of Energy, Washington, DC.
Document Type Technical Report
NTIS Issue Number 200516
Radiation Dose Measurements of the Insertion Devices Using Radiachromic Film Dosimeters.
Radiation Dose Measurements of the Insertion Devices Using Radiachromic Film Dosimeters.
DE2004834029

  • Advanced photon source
  • Radiation doses
  • Dosimeters
  • Dosimetry
  • Dosemeters
  • Photographic film dosemeters
  • Film dosimetry
  • Calibration
  • Radiachromic film dosimeters
  • Insertion devices
  • Technical Information Center Oak Ridge Tennessee
Loading