The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

Fast, High Light Output Scintillator for Gamma Ray and Neutron Detection.


DE2004820558

Publication Date 2003
Personal Author Entine, G.; Shah, K. S.; Cirignano, L.; Glodo, J.; Van Loef, E. V.
Page Count 10
Abstract In radiation detection systems employing scintillation crystals for the detection of high-energy particles such as x-rays or neutrons, the scintillator often limits the performance of the system. Ideally, a scintillator should have a high light yield for good energy and position resolution, a fast response time for good time resolution and high density and atomic number Z for efficient x-ray detection. The latter property is of less importance in the case of (thermal) neutron detection. Obviously, there are many other criteria such as transparancy of the material to its own emission, ease of crystal growth, etc. However, there is no commercially available material that meets all these criteria and the choice for a particular scintillator is often a compromise among these and other factors.
Keywords
  • Scintillator counters
  • Gamma detection
  • Neutron detection
  • Crystal growth
  • Emission spectra
  • Phosphors
  • Decay
  • Photodiodes
  • Silicon
  • Thermal neutrons
  • Time resolution
  • Photomultipliers
Source Agency
  • Technical Information Center Oak Ridge Tennessee
Corporate Authors Radiation Monitoring Devices, Inc., Watertown, MA.; Department of Energy, Germantown, MD.
Supplemental Notes Sponsored by Department of Energy, Germantown, MD.
Document Type Technical Report
Title Note Fifth Semi-Annual Rept.
NTIS Issue Number 200413
Fast, High Light Output Scintillator for Gamma Ray and Neutron Detection.
Fast, High Light Output Scintillator for Gamma Ray and Neutron Detection.
DE2004820558

  • Scintillator counters
  • Gamma detection
  • Neutron detection
  • Crystal growth
  • Emission spectra
  • Phosphors
  • Decay
  • Photodiodes
  • Silicon
  • Thermal neutrons
  • Time resolution
  • Photomultipliers
  • Technical Information Center Oak Ridge Tennessee
Loading