Publication Date |
2001 |
Personal Author |
Wynne, A. E.; Stuart, B. C. |
Page Count |
38 |
Abstract |
LLNL measured the material removal rate from stainless steel, silicon carbide, rhenium, N5, hastalloy X, and titanium as a function of pulse fluence at a wavelength of 810 nm for pulse durations of 150 fs, 1.5 ps, 20 ps, and 500 ps. Measurements included electron microscopy of selected samples. The experiments in I were repeated for all materials but select pulse durations with the sample in a vacuum of base pressure 10 mTorr to determine if hole quality and ablation rate is improved. LLNL measured material removal rate from stainless steel, silicon carbide, rhenium, N5, hastalloy X, and titanium as a function of pulse fluence at a wavelength of 532 nm for pulse duration at 200 ns. |
Keywords |
|
Source Agency |
|
Corporate Authors |
Lawrence Livermore National Lab., CA.; Department of Energy, Washington, DC. |
Supplemental Notes |
Sponsored by Department of Energy, Washington, DC. |
Document Type |
Technical Report |
NTIS Issue Number |
200426 |