National Technical Reports Library - NTRL

National Technical Reports Library

The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

Saltwell Leak Detector Station Programmable Logic Controller (PLC) Software Configuration Management Plan (SCMP).


DE2003805460

Publication Date 2000
Personal Author Koch, M. R.
Page Count 28
Abstract This document provides the procedures and guidelines necessary for computer software configuration management activities during the operation and maintenance phases of the Saltwell Leak Detector Stations as required by HNF-PRO-309, Rev. 1, Computer Software Quality Assurance, Section 2.4, Software Configuration Management. The software configuration management plan (SCMP) integrates technical and administrative controls to establish and maintain technical consistency among requirements, physical configuration, and documentation for the Saltwell Leak Detector Station Programmable Logic Controller (PLC) software during the Hanford application, operations and maintenance. This SCMP establishes the Saltwell Leak Detector Station PLC Software Baseline, status changes to that baseline, and ensures that software meets design and operational requirements and is tested in accordance with their design basis.
Keywords
  • Leak detectors
  • Database management
  • Radioactive waste storage
  • Leaks
  • Computerized control systems
  • Storage facilities
  • Procedures
  • Guidelines
  • Computer codes
  • Computer software
Source Agency
  • Technical Information Center Oak Ridge Tennessee
Corporate Authors CH2M Hill Hanford Group, Inc., Richland, WA.; Department of Energy, Washington, DC.
Supplemental Notes Sponsored by Department of Energy, Washington, DC.
Document Type Technical Report
NTIS Issue Number 200319
Saltwell Leak Detector Station Programmable Logic Controller (PLC) Software Configuration Management Plan (SCMP).
Saltwell Leak Detector Station Programmable Logic Controller (PLC) Software Configuration Management Plan (SCMP).
DE2003805460

  • Leak detectors
  • Database management
  • Radioactive waste storage
  • Leaks
  • Computerized control systems
  • Storage facilities
  • Procedures
  • Guidelines
  • Computer codes
  • Computer software
  • Technical Information Center Oak Ridge Tennessee