The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

PFP Vault Operations Containers for Plutonium Handling and Storage Critical Characteristics.


DE2003804506

Publication Date 2000
Personal Author Bonadie, E. P.; Szempruch, R. W.
Page Count 26
Abstract This screening addresses the critical characteristics for food industry type cans and containers used for handling and storage of special nuclear materials at the Plutonium Finishing Plant (PFP). This revision lists Critical Characteristics for two (2) large filtered containers, and associated shielding over-packs. These new containers are cded 'Nuclear Material Containers' (NMCs). They are supplied in various sizes, which can be nested, one inside another. The PFP will use NMCs with volumes up to 8 quarts as needed to over-pack largely bulged containers. This screening address the use of the vented over-pack container for transport of largely bulged food pack containers (or those containers with a potential for release of contamination) to a glovebox.
Keywords
  • Radioactive waste storage
  • Containers
  • Plutonium
  • Radioactive materials
  • Specifications
  • Safety
  • Transportation of hazardous materials
  • Nuclear materials containers
  • Over-pack containers
Source Agency
  • Technical Information Center Oak Ridge Tennessee
Corporate Authors Fluor Hanford, Richland, WA.; Department of Energy, Washington, DC. Assistant Secretary for
Supplemental Notes Sponsored by Department of Energy, Washington, DC. Assistant Secretary for Environmental Management.
Document Type Technical Report
NTIS Issue Number 200316
PFP Vault Operations Containers for Plutonium Handling and Storage Critical Characteristics.
PFP Vault Operations Containers for Plutonium Handling and Storage Critical Characteristics.
DE2003804506

  • Radioactive waste storage
  • Containers
  • Plutonium
  • Radioactive materials
  • Specifications
  • Safety
  • Transportation of hazardous materials
  • Nuclear materials containers
  • Over-pack containers