National Technical Reports Library - NTRL

National Technical Reports Library

The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload PDF
Download

Pilot-Scale Test of Counter-Current Ion Exchange (CCIX) Using UOP IONSIV IE-911.


DE2001786812

Publication Date 2001
Personal Author Wester, D. W.; Leugemors, R. K.; Taylor, P. W.
Page Count 28
Abstract A pilot-scale test of a moving-bed configuration of a UOP IONSIV. IE-911 ion-exchange column was performed over 17 days at Severn Trent Services facilities. The objectives of the test, in order of priority, were to determine if aluminosilicate precipitation caused clumping of IE-911 particles in the column, to observe the effect on aluminum-hydroxide precipitation of water added to a simulant-filled column, to evaluate the extent of particle attrition, and to measure the expansion of the mass-transfer zone under the influence of column pulsing. The IE-911 moved through the column with no apparent clumping during the test, although analytical results indicate that little if any aluminosilicate precipitated onto the particles. A precipitate of aluminum hydroxide was not produced when water was added to the simulant-filled column, indicating that this upset scenario is probably of little concern. Particle-size distributions remained relatively constant with time and position in the column, indicating that particle attrition was not significant. The expansion of the mass-transfer zone could not be accurately measured because of the slow loading kinetics of the IE-911 and the short duration of the test; however, the information obtained indicates that back-mixing of sorbent is not extensive.
Keywords
  • Aluminum silicates
  • Ion exchange
  • Extraction columns
  • Precipitation
  • Aluminum hydroxides
Source Agency
  • Technical Information Center Oak Ridge Tennessee
Corporate Authors Pacific Northwest National Lab., Richland, WA.; Department of Energy, Washington, DC.
Document Type Technical Report
NTIS Issue Number 200302
Contract Number
  • AC06-76RLO1830
Pilot-Scale Test of Counter-Current Ion Exchange (CCIX) Using UOP IONSIV IE-911.
Pilot-Scale Test of Counter-Current Ion Exchange (CCIX) Using UOP IONSIV IE-911.
DE2001786812

  • Aluminum silicates
  • Ion exchange
  • Extraction columns
  • Precipitation
  • Aluminum hydroxides
  • Technical Information Center Oak Ridge Tennessee
  • AC06-76RLO1830
Loading