The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

Microsensors for In-Situ, Real-Time Detection and. Characterization of Toxic Organic Substances.


DE2001786753

Publication Date 2001
Personal Author Rajic, S.
Page Count 13
Abstract We have further developed and demonstrated the novel ORNL micro-calorimetric spectroscopy technique for the detections and characterization of toxic organic substances. In this technique target molecules were allowed to absorb on the surface of sub-femtojoule sensitive micromechanical thermal detectors. The absorption of molecules on the thermal detector surface causes a differential surface stress resulting in an initial 'trigger'. By exposing the thermal detector microstructure elements to different photon wavelengths, an extremely sensitive and unique photothermal signature response was obtained. We absorbed sub-monolayer levels of target chemicals onto the bi-material detector surfaces. We obtained infrared photothermal spectra for trace concentrations of several organics such as diisopropyl methylphosponate (DIMP), and trinitrotoluene (TNT) over the wavelength region 2.5 to 14.5 um. We found that in the wavelength region 2.5 to 14.5 um the photothermal spectra of DIMP and TNT exhibit a number of peaks and are in excellent agreement with traditional infrared absorption spectra found in the literature. Chemical detectors based on micro-calorimetric spectroscopy can be used to sensitively sense a relatively small number of molecules absorbed on a thermal detector surface. This photothermal signature resulting from photon irradiation and subsequent theram transfer can be used for improved chemical characterization.
Keywords
  • Microsensors
  • Toxic substances
  • Detection
  • Spectroscopy
  • Calorimeters
  • Orgnic compounds
  • In situ
  • Real time
Source Agency
  • Technical Information Center Oak Ridge Tennessee
Corporate Authors Oak Ridge National Lab., TN.; Department of Energy, Washington, DC.
Document Type Technical Report
NTIS Issue Number 200201
Contract Number
  • AC05-00OR22725
Microsensors for In-Situ, Real-Time Detection and. Characterization of Toxic Organic Substances.
Microsensors for In-Situ, Real-Time Detection and. Characterization of Toxic Organic Substances.
DE2001786753

  • Microsensors
  • Toxic substances
  • Detection
  • Spectroscopy
  • Calorimeters
  • Orgnic compounds
  • In situ
  • Real time
  • Technical Information Center Oak Ridge Tennessee
  • AC05-00OR22725
Loading