National Technical Reports Library - NTRL

National Technical Reports Library

The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

Hot Cell Facility Criticality Safety Assessment for Storage of Medical Isotope Targets and Process Waste.


DE2001782597

Publication Date 2001
Personal Author Mitchell, ; Romero,
Page Count 62
Abstract An assessment of the potential criticality hazard associated with isotope processing operations in the Hot Cell Facility has been accomplished in accordance with DOE-STD-3007-93. This assessment includes the consideration of the quantities, forms, and locations of fissile material that will exist in the HCF. Contingency analyses have been accomplished to evaluate the multiple events which could potentially result in a criticality event. These analyses included the effects of flooding and procedural errors. Validated calculational techniques have been used to evaluate all credible configurations of fissile material. A wide range of fissile arrays and hypothetical configurations were numerically analyzed to assess the potential for criticality. In all cases, the results indicated that fissile material arrays would remain subcritical in the HCF. The design features and administrative controls on which these analyses were based are identified.
Keywords
  • Radioactive waste storage
  • Medical supplies
  • Radiopharmaceuticals
  • Criticality
  • Hot cells
  • Safety analysis
  • Storage facilities
  • Targets
  • Precursor
Source Agency
  • Technical Information Center Oak Ridge Tennessee
Corporate Authors Sandia National Labs., Albuquerque, NM.; Department of Energy, Washington, DC.
Document Type Technical Report
NTIS Issue Number 200125
Contract Number
  • AC04-94AL85000
Hot Cell Facility Criticality Safety Assessment for Storage of Medical Isotope Targets and Process Waste.
Hot Cell Facility Criticality Safety Assessment for Storage of Medical Isotope Targets and Process Waste.
DE2001782597

  • Radioactive waste storage
  • Medical supplies
  • Radiopharmaceuticals
  • Criticality
  • Hot cells
  • Safety analysis
  • Storage facilities
  • Targets
  • Precursor
  • Technical Information Center Oak Ridge Tennessee
  • AC04-94AL85000