The WHOI buoy radiometer intercomparison took place during May and June, 2000 at the WHOI facility. The WHOI IMET, JAMSTEC Triton, and NOAA TAO buoy systems were operated from a beach site and the Brookhaven National Laboratory set up two Portable Radiation Package systems (P01 and P02) alongside the WHOI instrumentation on the roof of the Clark Building, about 300 m away. The BNL instruments were named 'P01' and 'P02' and were identical. Buoy instruments were all leveled to (+-)1(degree) to horizontal. The purpose of the project was to compare the buoy systems with precision measurements so that any differences in data collection or processing would be evaluated. BNL was pleased to participate so the PRP system could be evaluated as a calibration tool. The Portable Radiation Package is an integral component of the BNL Shipboard Oceanographic and Atmospheric Radiation (SOAR) system. It is designed to make accurate downwelling radiation measurements, including the three solar irradiance components (direct normal, diffuse and global) at six narrowband channels, aerosol optical depth measurements, and broadband longwave and shortwave irradiance measurements. |