National Technical Reports Library - NTRL

National Technical Reports Library

The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

Degradation and Failure Characteristics of NPP Containment Protective Coating Systems.


DE2001777889

Publication Date 2001
Personal Author Sindelar, R. L.
Page Count 42
Abstract Nuclear power plants (NPPs) must ensure that the emergency core cooling system (ECCS) or safety-related containment spray system (CSS) remains capable of performing its design safety function throughout the life of the plant. This requires ensuring that long-term core cooling can be maintained following a postulated loss-of-coolant accident (LOCA). Adequate safety operation can be impaired if the protective coatings which have been applied to the concrete and steel structures within the primary containment fail, producing transportable debris which could then accumulate on BWR ECCS suction strainers or PWR ECCS sump debris screens located within the containment. This document will present the data collected during the investigation of coating specimens from plants.
Keywords
  • Containment spray systems
  • Nuclear power plants
  • Protective coatings
  • Eccs
  • Loss of coolant
  • Failure mode analysis
  • Concretes
  • Steels
  • Materials testing
  • Water cooled reactors
Source Agency
  • Technical Information Center Oak Ridge Tennessee
Corporate Authors Department of Energy, Aiken, SC. Savannah River Site.; Department of Energy, Washington, DC.
Document Type Technical Report
NTIS Issue Number 200125
Contract Number
  • AC09-96SR18500
Degradation and Failure Characteristics of NPP Containment Protective Coating Systems.
Degradation and Failure Characteristics of NPP Containment Protective Coating Systems.
DE2001777889

  • Containment spray systems
  • Nuclear power plants
  • Protective coatings
  • Eccs
  • Loss of coolant
  • Failure mode analysis
  • Concretes
  • Steels
  • Materials testing
  • Water cooled reactors
  • Technical Information Center Oak Ridge Tennessee
  • AC09-96SR18500
Loading