The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

Irradiation Stability of Syringe and Valve Controllers of RadioGenix (TM) System.


DE141155047

Publication Date 2014
Personal Author Quigley, K.; Makarashvili, V.; Chemerisov, S.; Vandegrift, G. F.; Tkac, P.; Schluter, R.; Harvey, J.
Page Count 18
Abstract NorthStar Medical Technologies has developed the RadioGenix (formerly known as TechneGen) Generator System, which allows nuclear pharmacies to provide 99mTc for critical medical procedures using low-specific-activity molybdenum-99 (Mo-99) as source material. Molybdenum-99 is the parent isotope of technetium-99m (Tc-99m), an element used in approximately 85% of diagnostic imaging procedures. The RadioGenix System allows for the efficient separation and dose preparation of Tc-99m from Mo-99. There is an interest in determining the lifetime of the components that are used in the system, in particular, the controllers used for the syringe and valves. We performed (1) Monte Carlo N-Particle Transport (MCNPX) calculations to predict the dose rates these components would receive during operation and (2) an experimental study to measure the radiation stability of these controllers using a 3 MeV Van de Graaff electron accelerator. A tungsten photon converter was attached to the beam window so that the electronic components were irradiated with photons rather than electrons.
Keywords
  • Medical equipment
  • Controllers
  • Dose rate
  • Irradiation
  • Isotopes
  • Molybdenum 99
  • Medical procedures
  • Monte Carlo method
  • Pharmacies
  • Photons
  • Radiations
  • Stability
  • Technetium
  • Valves
  • Radiogenix system
Source Agency
  • Technical Information Center Oak Ridge Tennessee
NTIS Subject Category
  • 95C - Biomedical Instrumentation & Bioengineering
Corporate Authors Argonne National Lab., Idaho Falls, ID.; Department of Energy, Washington, DC.
Supplemental Notes Sponsored by Department of Energy, Washington, DC.
Document Type Technical Report
NTIS Issue Number 201503
Irradiation Stability of Syringe and Valve Controllers of RadioGenix (TM) System.
Irradiation Stability of Syringe and Valve Controllers of RadioGenix (TM) System.
DE141155047

  • Medical equipment
  • Controllers
  • Dose rate
  • Irradiation
  • Isotopes
  • Molybdenum 99
  • Medical procedures
  • Monte Carlo method
  • Pharmacies
  • Photons
  • Radiations
  • Stability
  • Technetium
  • Valves
  • Radiogenix system
  • Technical Information Center Oak Ridge Tennessee
  • 95C - Biomedical Instrumentation & Bioengineering
Loading