National Technical Reports Library - NTRL

National Technical Reports Library

The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload XML
Download

Linking Saudi Arabia Loran-C Chain to Mediterranean Chain.


ADA497084

Publication Date 1987
Personal Author Samuel, S.
Page Count 9
Abstract The National Institute for Standards (NIS) is maintaining the Egyptian National Standards. International comparisons of NIS Frequency standard are continuously carried out. To obtain the required traceability, the most widely used system for time dissemination has been the navigational system of the U.S. Coast Guard Loran-C. The only chain that was available for timing in Cairo, Egypt was the Mediterranean (7990). The NIS receives the Loran-C signals from Sellia Marina (7990-M) and Kargabarun (7990-Y). The data are stored and compared with the data received from BIH at Paris and USNO at Washington, DC. By 1985, however, two chains covering Saudi Arabia, came into operation. Since both Loran-C chains can be received at NIS, which is nicely situated between them, it was obvious that NIS can contribute to link them together. Kargabarun, Turkey (7990-Y) of the Mediterranean chain is at 1244 km from NIS and Ash Shaykh Homayd, (8990x) of the North Saudi Arabia at 408 km. This paper presents the results obtained from the two Loran-C chains and comparisons with reports from BIH and USNO. If the necessary arrangements are made, continuous comparisons can be done and information sent to all interested organizations.
Keywords
  • Loran
  • Frequency standards
  • Time
  • Standards
  • Global positioning system
  • Navigation
  • Accuracy
  • Signals
  • Nis(National institute of standards)
Source Agency
  • Non Paid ADAS
Corporate Authors National Inst. for Standards, Cairo (Egypt).
Supplemental Notes Published in the Proceedings of the Nineteenth Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting, held in Redondo Beach, CA, on 1-3 December 1987.
Document Type Technical Report
NTIS Issue Number 200917
Linking Saudi Arabia Loran-C Chain to Mediterranean Chain.
Linking Saudi Arabia Loran-C Chain to Mediterranean Chain.
ADA497084

  • Loran
  • Frequency standards
  • Time
  • Standards
  • Global positioning system
  • Navigation
  • Accuracy
  • Signals
  • Nis(National institute of standards)
  • Non Paid ADAS
Loading