National Technical Reports Library - NTRL

National Technical Reports Library

The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:
Download PDFDownload PDF
Download

Electrospray LC/MS Detection of EA 2192 in Aqueous Solution.


ADA382406

Publication Date 2000
Personal Author Rohrbaugh, D. K.; Elizy, M. W.
Page Count 19
Abstract This report describes efforts to detect EA 2192, S-2- (DIISOPROPYLAMINO)ETHYL methylphosphonothioic acid, in aqueous solutions below the drinking water standard level of 20 ppb. LC/MS electrospray ionization and tandem MS detection using a parent ion of 240 m/z and a product ion of 128 m/z were applied to obtain the desired analytical sensitivity, selectivity, and reproducibility. From replicate analyses of a 10-ppb standard, a method detection limit (MDL) of 1-2 ppb in water was obtained. The method was also applied to EA 2192 detection in aqueous charcoal extract with similar results. Additional sample cleanup to remove interference is required, however, before the method can be applied to more complex decontamination matrices.
Keywords
  • Decontamination
  • Vx agent
  • Liquid chromatography
  • Chemical ordnance
  • Chemical agent detectors
  • Vesicants
  • Mass spectrometry
  • Aqueous solutions
  • Ea 2192
  • Electrospray ionization
  • Diisopropylamino-ethyl- methylphosphonothioic acid
  • Mdl(Method detection limit)
Source Agency
  • Non Paid ADAS
NTIS Subject Category
  • 74D - Chemical, Biological, & Radiological Warfare
Corporate Authors Edgewood Chemical Biological Center, Aberdeen Proving Ground, MD.
Document Type Technical Report
Title Note Final rept. Sep-Dec 1999.
NTIS Issue Number 200102
Electrospray LC/MS Detection of EA 2192 in Aqueous Solution.
Electrospray LC/MS Detection of EA 2192 in Aqueous Solution.
ADA382406

  • Decontamination
  • Vx agent
  • Liquid chromatography
  • Chemical ordnance
  • Chemical agent detectors
  • Vesicants
  • Mass spectrometry
  • Aqueous solutions
  • Ea 2192
  • Electrospray ionization
  • Diisopropylamino-ethyl- methylphosphonothioic acid
  • Mdl(Method detection limit)
  • Non Paid ADAS
  • 74D - Chemical, Biological, & Radiological Warfare
Loading