National Technical Reports Library - NTRL

National Technical Reports Library

The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:

Expanded Large Scale Gap Test.


ADA179406

Publication Date 1987
Personal Author Liddiard, T. P.; Price, D.
Page Count 54
Abstract The increased use of very shock insensitive high explosives has produced a need for larger test systems than are normally used for determining gap sensitivities. Relatively little work has been done using acceptor diameters that are larger than 40 or 50 mm. The acceptor diameters in the usual tests are not large enough to give reliable results for the explosives that have large detonation-failure diameters. It follows, then, that the acceptor diameter of the gap test should be substantially larger than the equivalent failure diameter of the acceptor material. If it is otherwise, the gap-test results could be misleading. The objective of this work is to study a new gap test, designed for relatively shock insensitive explosives, by relating its test results to those of a current standardized test. In particular, we wish to establish the relationship between card gap sensitivities in two sizes, the standard NOL (NSWC) Large Scale Gap Test (LSGT) and the new test, the Expanded Large Scale Gap Test (ELSGT).
Keywords
  • Explosives
  • Shock
  • Sensitivity
  • Diameters
  • Electron acceptors
  • Materials
  • Sizes(Dimensions)
  • Failure
  • Standardization
  • Tetrafluoroethylene resins
  • Hmx
  • Gap tests
Source Agency
  • Non Paid ADAS
NTIS Subject Category
  • 79A - Ammunition, Explosives, & Pyrotechnics
Corporate Authors Naval Surface Weapons Center, Silver Spring, MD.
Document Type Technical Report
Title Note Technical rept.
NTIS Issue Number 198715
Expanded Large Scale Gap Test.
Expanded Large Scale Gap Test.
ADA179406

  • Explosives
  • Shock
  • Sensitivity
  • Diameters
  • Electron acceptors
  • Materials
  • Sizes(Dimensions)
  • Failure
  • Standardization
  • Tetrafluoroethylene resins
  • Hmx
  • Gap tests
  • Non Paid ADAS
  • 79A - Ammunition, Explosives, & Pyrotechnics
Loading