The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:

Load Tests of a Wood Floor over a Basement.


ADA092688

Publication Date 1980
Personal Author Longinow, A.; Joyce, R. P.
Page Count 99
Abstract The results of an experimental study which was conducted to determine the strength of residential, wood floor systems over basements to uniform static load are presented in this report. A single family residence which was slated for demolition was acquired and load tested. Two load tests were conducted. The first load test was concerned with the strength of the as-built floor system. One half of the floor system was instrumented and loaded to collapse. Failure was experienced as 185.4 psf. The second load test was concerned with the strenth of an expediently upgraded floor system. The remaining half of the floor system was upgraded by placing a studwall in the longitudinal direction halfway between the exterior wall and the girder in each of the two spans. The floor was loaded to 559.3 psf. At this load the test was terminated due to reasons of safety. The floor system did not fail. Additional tests were conducted in the laboratory on the unfailed portions of the floor system. This consisted of three 'simple beam' tests of samples consisting of two joists with flooring attached. The load was uniformly distributed. The loading in each case was accomplished using solid concrete block. Probability of people survival estimates are included for two shelter conditions. In the first, the shelter is assumed to consist of the as-built basement with one foot of soil over the floor for radiation protection. In the second, the shelter is assumed to consist of the expediently upgraded basement with one foot of soil for radiation protection. The probability of people survival is estimated against blast effects produced by the detonation of a single 1-MT nuclear weapon.
Keywords
  • Floors
  • Static loads
  • Buildings
  • Housing(Dwellings)
  • Structural members
  • Beams(Structural)
  • Displacement
  • Failure(Mechanics)
  • Destructive tests
  • Deflection
  • Mechanical properties
  • Shelters
  • Basements
  • Nuclear explosions
  • Blast
  • Joists
Source Agency
  • Non Paid ADAS
NTIS Subject Category
  • 89D - Structural Analyses
  • 89G - Construction Materials, Components, & Equipment
Corporate Authors IIT Research Inst., Chicago, IL.
Document Type Technical Report
Title Note Final rept. 13 Jun 78-6 Jun 80.
NTIS Issue Number 198108
Contract Number
  • DCPA01-78-C-0223
Load Tests of a Wood Floor over a Basement.
Load Tests of a Wood Floor over a Basement.
ADA092688

  • Floors
  • Static loads
  • Buildings
  • Housing(Dwellings)
  • Structural members
  • Beams(Structural)
  • Displacement
  • Failure(Mechanics)
  • Destructive tests
  • Deflection
  • Mechanical properties
  • Shelters
  • Basements
  • Nuclear explosions
  • Blast
  • Joists
  • Non Paid ADAS
  • 89D - Structural Analyses
  • 89G - Construction Materials, Components, & Equipment
  • DCPA01-78-C-0223