National Technical Reports Library - NTRL

National Technical Reports Library

The National Technical Information Service acquires, indexes, abstracts, and archives the largest collection of U.S. government-sponsored technical reports in existence. The NTRL offers online, free and open access to these authenticated government technical reports. Technical reports and documents in its repository may be available online for free either from the issuing federal agency, the U.S. Government Publishing Office’s Federal Digital System website, or through search engines.




Details
Actions:

On the Interpretation of the Output of Hot-Film Anemometers and a Scheme of Dynamic Compensation for Water Temperature Variation.


AD784912

Publication Date 1973
Personal Author Tan-Atichat, J.; Nagib, H. M.; Pluister, J. W.
Page Count 55
Abstract Using a special calibration tunnel developed during the course of this study, the static and dynamic response of several kinds of commercially available hot-film probes with single and multiple sensors of the cylindrical-fiber type are examined. The effects of different parameters, including those of the anemometer bridge, on the output and performance of the probes are evaluated. In particular, the consequences of variations in water temperature on the hot-film anemometer output are determined. (Modified author abstract)
Keywords
  • Anemometers
  • Temperature control
  • Films
  • Water
  • Response
  • Hot film anemometers
Source Agency
  • Air Force
NTIS Subject Category
  • 94K - Laboratory & Test Facility Design & Operation
Corporate Authors Illinois Inst of Tech Chicago Dept of Mechanics Mechanical and Aerospace Engineering; Air Force Office of Scientific Research, Arlington, VA.
Document Type Technical Report
Title Note Scientific rept.
NTIS Issue Number 197423
On the Interpretation of the Output of Hot-Film Anemometers and a Scheme of Dynamic Compensation for Water Temperature Variation.
On the Interpretation of the Output of Hot-Film Anemometers and a Scheme of Dynamic Compensation for Water Temperature Variation.
AD784912

  • Anemometers
  • Temperature control
  • Films
  • Water
  • Response
  • Hot film anemometers
  • Air Force
  • 94K - Laboratory & Test Facility Design & Operation